Anode cap is designed to seal and protect the critical connection between the lead wire and anode.
It provides stress relief, moisture proofing and electrical insulation at the lead wire exit point. It is the ideal solution to the problem of premature system failure due to corrosion causing lead wire to come out of the anode.
It is made from a highly Cross-linked Polyolefin material. Rubber based mastic coating inside the cap adheres to Anode material and wire insulation which provides water tight sealing according to IP 68 (Ingress Protection).
Test Items |
Test Method |
Test Requirements |
Tensile strength |
ASTM D 2671 |
10MPa min. |
Ultimate elongation |
ASTM D 2671 |
200% min. |
Tensile strength after |
ASTM D 2671 |
10MPa min. |
Aging at 150℃ for 168hrs |
||
Ultimate elongation after |
ASTM D 2671 |
100% min. |
Aging at 150℃ for 168hrs |
||
Heat shock at 200℃/30min |
ASTM D 2671 |
No cracking, dropping |
Density |
ASTM D 792 |
1.2~1.3g/cm3 |
Dielectric strength |
IEC 60243 |
10kV/mm(2.5mm) min. |
Volume resistivity |
ASTM D 2671 |
1012Ω.cm min. |
Low temperature flexibility |
ASTM D 2671 Proc.C |
No cracking |
-40℃/4hrs |
||
Permittivity |
ASTM D 150 |
3 (nom.) |
Tracking
resistance |
ASTM D 2303 |
No tracking |